AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual Page - 39/73
The CNA#18 potentiometer modulates the current in the
proportional valve connected to the pin#8 of the MDI-
PRC. This proportional valve is normally closed (oil does
not pass-through when de-energized) and directly
connected between the pump and the tank: to do a Lifting
function the voltage into the Proportional Valve is turned
fully On, to direct the oil into the tank before the pump
contactor closes. Then the current in the Proportional
Valve reduces (meanwhile the CNA#18 potentiometer
increases) to accelerate the Lifting.To do a Lowering
function, the current in the proportional valve
progressively increases (meanwhile the CNA#18
potentiometer increases) to accelerate the Lowering.
- 3: Only the Main Lifting/Lowering pair (CNB#9 and CNB#8)
is used to handle an On/Off Lifting and a proportional
Lowering. (There is only one proportional valve connected
to the pin#8 of the MDI-PRC to modulate the Lowering).
The CNB#9 input is the Lifting request enabling the pump
contactor on CNA#4.
The CNB#8 input is the Lowering request to enable the
On/Off descent valve connected on CNA#6.
The CNA#18 potentiometer modulates the current in the
lowering proportional valve (pin#8 MDI-PRC) when the
Lowering request is active. To do a Lowering function, the
current in the proportional valve progressively increases
(meanwhile the CNA#18 potentiometer increases) to
accelerate the Lowering.