Page - 20/73 AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual
A18 CPOTB Brake potentiometer wiper.
A19 ENC A Encoder Channel A.
A20 ENC B Encoder Channel B.
9.1.2 CNB connector
B1 KEY Connected to the power supply through a microswitch
(KEY) with a 6.3-10A fuse in series (this could be
mounted on the AC1 cover).
B2 CM Common of FW / BW / SR1 / SR2 / TILLER / H&S /
BELLY / LIFTING / LOWERING microswitches. This
connection supplies a key voltage level.
B3 TILLER Tiller request input. Must be connected to the tiller
microswitch, active high.
B4 H&S Hard & Soft request input. Must be connected to the
Hard & Soft microswitch, active high.
B5 BACKWARD Backward direction request input. Must be connected
to the backward direction microswitch, active high.
B6 FORWARD Forward direction request input. Must be connected to
the forward direction microswitch, active high.
B7 BELLY Quick inversion function input; must be connected to
the Belly microswitch; it is active high.
B8 LOWERING Lowering request input, active high.
B9 LIFTING Lifting request input, active high.
B10 CPOT Accelerator potentiometer wiper.
B11 NPOT Negative of accelerator unit, tested for wire
disconnection diagnosis.
B12 PPOT Potentiometer positive: 10V output; keep load > 1K.
9.1.3 CNC connector
C1 PCLRXD Positive serial reception.
C2 NCLRXD Negative serial reception.
C3 PCLTXD Positive serial transmission.
C4 NCLTXD Negative serial transmission.
C5 GND Negative console power supply.
C6 +12 Positive console power supply.
C7 FLASH Must be connected to C8 for the Flash memory
programming (if used).
C8 FLASH Must be connected to C7 for the Flash memory
programming (if used).