- 15/18/20BT-7, 16/18/20B-7 Traction Master (03) Setup.
Code
ADJUSTMENTS
(Service
level)
245
SET POT BRK MIN
246
SET POT BRK MAX
145
SET BATTERY TYPE
140
ADJUST BATTERY
249
MAX STEER RIGHT
243
MAX STEER LEFT
152
SET STEER 0-POS.
246
SET STEER RIGHT
241
SET STEER LEFT
249
THROTTLE 0 ZONE
252
THROTTLE X POINT
253
THROTTLE Y POINT
248
ADJUSTMENT#2 BDI
249
ADJUSTMENT#1 BDI
157
ADJUSTMENT#3
251
MAIN CONT. VOLT.
252
AUX OUTPUT VOLT.
156
ADJUSTMENT#4
242
SPEED FACTOR
This parameters adjusts the Electric brake coil voltage (PWM output C28).
This parameter determines the motor temperature level at which theMotor temperature” alarm is
signalled. The range is from 0 °C to 200 °C with 1 °Csteps. This parameter must be adjusted only if the
“Set temperature(menu“Set option”) parameter is programmed “Analog”.
Speed Factor = (88 * rr * p) / Ø Where: rr = total gearbox reduction ratio, p = number of pair pole of the
motor (2), Ø = traction wheel diameter expressed in centimeters (cm)
It adjusts the lower level of the no-load battery discharge table. See also Dual ac2 manual
It adjusts the upper level of the no-load battery discharge table. See also Dual ac2 manual
At each key-off battery charge is stored. At each key on the battery voltage is read and the battery
charge is estimated. The battery charge is updated only if the new estimated battery charge differs from
the stored one by the ADJUSTMENT #3 set %.
This parameters adjusts the Line contactor coil voltage (PWM output C26).
This parameter sets the max steering angle in left direction.
Deadband in the accelerator input curve (see also curve in the dual ac2 manual).
This parameter changes the characteristic of the accelerator input curve.
This parameter changes the characteristic of the accelerator input curve.
Steering poti output voltage when the wheels are fully turned right (maximum of the steering poti range).
Steering poti output voltage when the wheels are fully turned left (minimum of the steeringpoti range).
Steering poti output voltage when the wheels are straight
This parameter sets the max steering angle in right direction.
It records the minimum value of braking pedal potentiometer when the braking pedal switch is closed;
the procedure is similar to the "Program Vacc" function (see chapter 9.3 of the manual). This procedure
must be carried out only if the "Pedal braking" option is programmed as "Analog".
It records the maximum value of braking pedal potentiometer when the braking pedal is fully pressed;
the procedure is similar to the "Program Vacc" function (see chapter 9.3). This procedure must be carried
out only if the "Pedal braking" option is programmed as "Analog".
Nominal battery voltage.
Fine adjustment of the battery voltage measured by the controller (ZAPI production line adjusted).
0.9 V
20%
36V
36V
5%
63%
25%
LEVEL = 3
LEVEL = 3
0.9V
2.7V
90 ˚(3W) / 97 ˚(4W)
90 ˚(3W) / 75 ˚(4W)
9.0 V
48 V
51.40 V
4.4V
145 ˚
81
Parameter explanation.